Enquiry

NB IoT Box LITE PRESSURE

Monitor pressure in gas and water supply networks automatically.

The NB IoT Box LITE PRESSURE is a battery-powered data logger for capturing, storing and remotely transmitting pressure readings.

Depending on the version, one or two pressure sensors can be connected, for example to monitor network pressure or to measure inlet and outlet pressure at a gas pressure regulating station.

Pressure values are captured at adjustable intervals and transmitted over the NB-IoT mobile network to the VERAUT web portal VERILOG or an existing data acquisition system.

When the device detects that a set pressure limit has been exceeded or undershot, it starts an additional alarm transmission, so that pressure deviations can be detected early and action taken.

The data logger is battery-powered and needs no external power supply. Correspondingly approved versions can also be used in Zone 2 hazardous areas.

  • 1 or 2 pressure sensors
  • NB-IoT
  • Limit alarms
LITE PRESSUREInlet pressureOutlet pressureRegulatorGas or waterNB-IoTVERILOG or your system
NB IoT Box LITE PRESSURE with two connected pressure transmitters1234

The NB IoT Box LITE PRESSURE in detail

The NB IoT Box LITE PRESSURE is a battery-powered data logger for capturing, storing and remotely transmitting pressure readings. Depending on the version, it has connections for one or two pressure sensors. The captured values are stored internally and transmitted over the NB-IoT mobile network.

  1. 1

    Data logger in an IP65 housing

    The housing contains the electronics, the NB-IoT radio module, an integrated antenna and a replaceable lithium primary battery. It is intended for outdoor mounting within the specified ambient conditions.

  2. 2

    Separate cable entry for each pressure sensor

    Each pressure sensor is connected to its sensor input on the data logger by its own cable. The cables enter the housing through cable glands. Depending on the version, one or two pressure sensors can be connected.

  3. 3

    Sensors for absolute or relative pressure

    Pressure sensors with a 0 to 20 mA or 4 to 20 mA analogue current output, depending on the sensor. Depending on the task, a sensor for absolute pressure or relative (gauge) pressure is chosen; ranges run from 0 to 100 mbar up to 0 to 100 bar.

  4. 4

    Separate mounting of data logger and sensor

    The pressure sensors are installed at the intended pressure tapping points. Using the sensor cables, the data logger can be mounted away from them, for example on a wall or a suitable mounting frame.

Shown: version with two pressure sensors.

Record pressure profiles instead of reading single values

Remote measuring points in gas and water supply networks do not always have a power supply. Installing conventional measurement and transmission equipment can therefore mean extra effort. At such points, pressure is sometimes checked by manual readings or temporary measurements on site, so pressure fluctuations between readings cannot be fully traced.

Today

  • Single measurements without a complete record of the pressure over time
  • Conventional systems may need an external power supply or additional installation work
  • Pressure deviations between manual readings may go unnoticed

With the NB IoT Box LITE PRESSURE

  • Regular pressure measurement with stored readings
  • Battery-powered data logger for wall mounting without an additional control cabinet
  • Event-driven alarm transmission when a limit violation is detected

Pressure measurement, data transmission and alarms

The data logger captures pressure values at configurable measuring intervals and stores them in its internal memory. The stored values are sent over NB-IoT to the target system at the set transmission interval. If a measurement shows that a set pressure limit has been exceeded or undershot, an additional alarm transmission is triggered. The example below shows regular pressure measurement and event-driven alarm transmission.

High-pressure alarmLow-pressure alarmAlarm transmitted on detectionshorter measuring interval →hourly transmission00:0012:0024:00
  1. 1 · Measure

    Measuring interval adjustable from 1 to 60 minutes

    The measuring interval can be set between 1 and 60 minutes. Captured values are stored in non-volatile memory. How long the memory lasts depends on the measuring interval and the number of channels.

  2. 2 · Transmit

    Regular transmission at adjustable intervals

    By default the stored pressure values are transmitted once an hour. Alternatively, daily transmission of the recorded values can be set. The stored values show the pressure profile at each measuring point for display and analysis.

  3. 3 · Alarm

    Alarm on limit deviation

    If the data logger detects in a measurement that a set pressure limit has been exceeded or undershot, it starts an unscheduled alarm transmission. If configured, the measuring interval can be shortened while an alarm is active.

VERILOG displays the recorded pressure profiles and alarm events. If configured, alarm messages can be forwarded by e-mail to defined recipients. Alternatively, measurement and alarm data can be sent via MQTT to an existing data acquisition or control system.

Note: Limit monitoring is based on the captured readings. Once a limit deviation is detected, an event-driven transmission is started. The actual transmission time depends, among other things, on the mobile connection.

Pressure monitoring at one or two measuring points

Each pressure measuring point has its own sensor input. Whether one or two sensors are needed depends on the measuring task. The device versions can be used for suitable pressure measuring tasks in gas and water supply networks.

  • 1 measuring point

    Pressure monitoring at network nodes and end points

    One pressure sensor captures the pressure at a defined measuring point. The stored values show pressure fluctuations over the day and week. At network end points you can check, for example, whether the required supply pressure is maintained even at high consumption.

  • 2 measuring points

    Inlet and outlet pressure

    In gas pressure regulating and transfer stations, two sensors can capture the inlet pressure upstream and the outlet pressure downstream of the pressure regulator. The recorded values show how the outlet pressure behaves under different inlet pressure and consumption conditions.

Further applications

  • Network analysis: pressure profiles as additional data for hydraulic network calculations and the assessment of operating states
  • Detection of conspicuous pressure changes that may indicate leaks or other changes in network operation
  • Commissioning and construction monitoring: temporary pressure measurements documenting pressure behaviour during certain operating or construction phases
  • Storage facilities: pressure monitoring at remote measuring points, provided sensors and device version suit the operating conditions
  • Pressure measurement in gas and water supply networks within the approved measuring and operating ranges
  • Industrial applications: monitoring of process and supply pressures in suitable plants, including hazardous areas in line with the existing approval

Choosing the right pressure sensor for your measuring point

The pressure sensors are selected to match the technical requirements of each measuring point, in particular the medium, the required pressure range and the ambient conditions at the installation site. For the selection we need the following information:

InformationRelevance for the selection
MediumThe medium to be measured, for example natural gas or drinking water. Materials, seals and wetted parts of the sensor must suit the medium.
Required pressure rangeThe expected minimum and maximum operating pressure and whether absolute or relative pressure is to be measured. The suitable sensor is chosen on this basis. Sensor ranges from 0 to 100 mbar up to 0 to 100 bar are available.
Installation and ambient conditionsMounting position, ambient temperature, protection class, any hazardous-area zone classification and the cable length needed between sensor and data logger.

The available ranges and technical properties of the sensors are given in the corresponding datasheets.

Which pressure measuring task would you like to implement?

Tell us the medium, the intended pressure range, the number of measuring points and the installation conditions. We check the technical requirements and propose a suitable combination of sensors and data logger and a suitable mounting version. On request we support you with a pilot project.

Phone +43 732 386361-0
Request a pilot project

Connect one or two pressure sensors and transmit readings

The connected pressure sensors provide an analogue current signal of 0 to 20 mA or 4 to 20 mA. The data logger captures the analogue signals, converts them into pressure values based on the configured sensor range and transmits the data in encrypted form to the target system.

Inputs

  • Analogue inputsDepending on version, one or two analogue inputs for 0 to 20 mA or 4 to 20 mA
  • Sensor connectionSeparate cable gland for each sensor input
  • SensorsCompatible sensors for absolute or relative pressure with a range matched to the task
NB IoT Box LITE PRESSURENB IoT Box LITE PRESSUREcaptures, stores and transmits pressure values

Transmission

  • NB-IoTNB-IoT (LTE Cat-NB2) in the licensed mobile network; no additional gateway required
  • ProtocolEncrypted data transmission via MQTT
  • AntennaIntegrated antenna; external antenna as an option on request
  • TimeAutomatic time synchronisation via SNTP; configurable time zones and daylight saving time

Target systems

  • VERILOGDisplay and analysis of pressure profiles, alarm messages on limit deviations and export of measurement data
  • Your systemConnection to existing data acquisition and control systems via MQTT

More than 10 years battery life with hourly transmission

over10years

The stated battery life is a guide value for operation with hourly transmission and favourable NB-IoT reception conditions (ECL 0). Between measurements and transmissions the data logger runs in an energy-optimised state. Shorter measuring intervals, a second sensor and additional alarm transmissions increase energy consumption.

Mark at 10 years: stated guide value for hourly transmission under favourable reception conditions (ECL 0).

Battery life depends on

  • Measuring and transmission interval
  • Number of pressure sensors
  • Number of additional alarm transmissions
  • NB-IoT reception conditions at the installation site
  • Ambient temperature

With every transmission the battery is checked under load. If it falls below a set threshold, VERILOG can send a warning by e-mail. The lithium thionyl chloride battery (Li-SOCl₂) is replaceable; stored readings and device settings are retained when it is changed.

Technical data of the NB IoT Box LITE PRESSURE

The following data is an extract from the technical datasheet. The currently valid product documents, the operating instructions and the approval documents are binding.

Pressure measurement
Measuring channelsOne or two sensor inputs depending on version, with separate cable entries
Analogue inputsOne or two inputs for 0 to 20 mA or 4 to 20 mA
Sensor rangesDepending on sensor from 0 to 100 mbar up to 0 to 100 bar, absolute or relative pressure
Explosion protection
Area of useHazardous areas of Zone 2
MarkingEx II 3G Ex ic IIA T4 Gc
Measurement and alarms
Measuring intervalAdjustable from 1 to 60 minutes
Transmission intervalAdjustable from one minute; hourly by default, alternatively daily transmission of the stored values
Pressure limit alarmUnscheduled transmission when a set pressure limit is detected as exceeded or undershot
Alarm behaviourOptionally shorter measuring interval while an alarm is active
Memory and time
Data memoryNon-volatile internal memory for readings and alarm events
Battery changeStored readings and device settings are retained
Time synchronisationAutomatic synchronisation via SNTP at configurable intervals; time zones and daylight saving time
Display of readingsNo integrated display; readings shown in VERILOG or the connected target system
Communication
TechnologyNB-IoT, LTE Cat-NB2, licensed spectrum
ProtocolMQTT with encrypted data transmission
AntennaInternal; external antenna on request
Remote maintenanceRemote configuration and firmware updates via MQTT
Target systemsVERILOG or compatible data acquisition and control systems
Power supply
BatteryReplaceable lithium thionyl chloride battery (Li-SOCl₂); use approved battery types only
Battery lifeGuide value over 10 years under defined operating conditions; depends among other things on measuring and transmission interval, number of sensors, alarm frequency, reception conditions and ambient temperature
Battery monitoringUnder load with every transmission, warning by e-mail via VERILOG
Mechanics and environment
Housing protectionIP65; outdoor mounting within the specified ambient conditions
DimensionsApprox. 140 × 100 mm without pressure sensors
MountingWall mounting via integrated mounting lugs
Operating temperature−20 °C to +55 °C
Relative humidity10 to 90 %, non-condensing
EnvironmentRoHS-compliant; disposal according to applicable WEEE and battery regulations
Pressure sensor for gas networks
MarkingEx II 1G Ex ia IIC T6 Ga, intrinsically safe, up to Zone 0
Accuracy±0.2 % of full scale; up to 100 mbar ±1 %
MediumNatural gas and non-corrosive gases
OverloadTest pressure 1.25 × MOP without permanent deformation
ConnectionsProcess 1/4″ NPT male; electrical M12 × 1
Material, protectionStainless steel, IP65
TemperatureAmbient −20 to +85 °C, medium −30 to +105 °C

Explosion protection under ATEX for use in Zone 2

In gas pressure regulating and metering stations and along gas lines, an explosive gas-air mixture can form. Equipment in such hazardous areas needs explosion protection under ATEX, the European rules for these areas. The NB IoT Box LITE PRESSURE is approved for Zone 2:

Zone 2

An explosive mixture is not likely to occur in normal operation, or only briefly.

The marking, read part by part

  1. ExExplosion protection
  2. IIEquipment group II: all areas except mining
  3. 3GCategory 3 for gas, suitable for Zone 2
  4. Ex icType of protection: intrinsic safety, level c
  5. IIAGas group IIA, for example natural gas
  6. T4Temperature class T4: surface max. 135 °C
  7. GcEquipment protection level for Zone 2
  • Intrinsically safe gas sensor

    The pressure sensor for gas networks is intrinsically safe (Ex ia) and approved up to Zone 0.

  • No legal metrology

    The data logger is used purely for data acquisition and is not subject to the Measuring Instruments Directive (MID).

  • Binding documents

    For use in hazardous areas, the EC type examination certificate and the operating instructions apply.

In practice: critical nodes in a distribution network

Two pressure channels at critical nodes, analysed hourly: an example from a distribution network.

Network operation

Distribution network operator

Starting point
Critical network nodes were to be monitored permanently. There is neither a control cabinet nor a power supply.
Solution
NB IoT Box LITE PRESSURE with two sensors for inlet and outlet pressure, battery-powered. The pressure values are transmitted hourly to the data acquisition system.
Result
Conspicuous pressure changes are detected early and can be checked specifically, with no infrastructure of its own at the network node.

Documents

Frequently asked questions

Is there a display on the device?

No. The data logger has no display. You see pressure values, alarms and battery status in VERILOG or in your own system.

Is absolute or relative pressure measured?

That depends on the sensor used. For each measuring point we define whether absolute pressure or relative pressure (gauge pressure against ambient pressure) is captured.

Can limits and intervals be changed later?

Yes, remotely via the MQTT broker, without a trip to the measuring point. Firmware updates are also delivered remotely.

Do I have to use VERILOG?

No. Measurement and alarm data can also be sent via MQTT directly to an existing data acquisition or control system.

NB IoT Box LITE PRESSURE or NB IoT Box MINI?

The NB IoT Box LITE PRESSURE specialises in pressure. If meters or volume converters are also to be read at the same station, the NB IoT Box MINI is the better fit; besides analogue inputs for sensors, it has meter and serial interfaces.

Plan pressure monitoring at your measuring points

Tell us which measuring points you want to monitor, for example network end points or gas pressure regulating stations. We define sensors, measuring intervals and limits together with you.

Let's talk about your metering point.

Briefly describe your application, meter type, installation site and hazardous area zone. We reply within up to three working days.

VERAUT GmbH · Derfflingerstraße 14/C/3 · 4020 Linz, Austria
+43 732 386361-0 · info (at) veraut.com

What is it about?
0